Inquiry
Form loading...
Products Categories
Featured Products

FN7-12 Indoor load break switch (LBS) 12KV

FN7- 12R(L) model indoor AC HV load break switch-fuse combination apparatus is developed and designed based on international technology and national power supply requirement, it passed all type tests and trial-operation inspections. The apparatus conforms to IEC420: AC LOAD BREAK SWITCH AND  FUSE COMBINATION APPARATUS(1990 EDITION) Compared to international product it keeps up with technical level with small volume and light weight. It is applicable in ring main unit and prefabricated substations as well as 12kv line and power distribution system. The product realizes three working positions: power making. power breaking and earth. It applies to power system of rated voltage 6- 12kv, 50/60HZ breaking load current over load current and short-circuit current.

    Adhering to your principle of "quality, assistance, performance and growth", we have now gained trusts and praises from domestic and international customer for High reputation Rmu Indoor Sf6 Gas Isolation Breaker 20kv 22kv 24kv Air Load Break Switch Load Switch Housing Disconnectors, We glance forward to giving you with our solutions while in the in the vicinity of future, and you will come across our quotation may be very affordable and the top quality of our merchandise is extremely outstanding! High reputation Sf6 Load Switch Breaker and Load Switch Breaker, Our market share of our products and solutions has greatly increased yearly. If you are interested in any of our solutions or would like to discuss a custom order, make sure you feel free to contact us. We have been looking forward to forming successful business relationships with new clients around the world in the near future. We have been looking forward to your inquiry and order.

    Environment condition

    1. The altitude: under 1000M.
    2. The ambient temperature: -25℃-+40℃.
    3. The relative humidity of air: monthly≤90%, daily≤95%.
    4. Amplitude: Earthquake degree 8.
    5. Application occasions should free from fire, inflammables, explosives, corrosives and severe vibration.

     

     

    Technical parameter

    NO

    Item

    Units

    Technical parameters

    1

    Rated voltage

    kV

    10

    2

    Maximum working voltage

    kV

    12

    3

    Rated current

    A

    200

    400

    630

    4

    Rated short-time withstand current(4s)

    kA

    6

    12.5

    20

    5

    Rated peak withstand current

    kA

    15

    31.5

    50

    6

    Rated closed loop breaking current

    A

    200

    400

    630

    7

    Rated loading breaking current

    A

    200

    400

    630

    8

    Rated loading breaking current (5%)

    A

    10

    20

    31.5

    9

    Rated short circuit closing current

    kA

    15

    31.5

    50

    10

    Power frequency withstand voltage

    kV

    42(Fracture:48)

     Lightning impulse withstand voltage

    75(Fracture:84)

    11

    Open/close operating torque

     N.m(N)

    90(180)

    100(200)

                 

     