Inquiry
Form loading...
Products Categories
Featured Products

Outdoor disconnector,CE Certified Outdoor Disconnector Switch FactoryGW5-40.5 Outdoor disconnector(isolate switch)40.5kv

GW5-40.5 Outdoor disconnector(isolate switch)40.5kv

GW5 is a double-column horizontal fracture center opening type, and a grounding switch can be attached to one or both sides. The isolating switch of 90° transmission adopts CS17 type manual operation mechanism for three-pole linkage operation; the isolation switch of 180° transmission adopts CJ6 type motor operation mechanism or CS17G type manual operation mechanism for three-pole linkage operation; the grounding switch adopts CS17G type manual operation mechanism. The three-pole linkage operation of the driving mechanism.

Product feature

1.Complete in specifications,high technical parameters is high, wide range. Additional, wide scope of application , it can be used for high layout. Installation way is flexible. 

2.Perfect sealing Performance and  Resistant To Rust 

3.Simple, reliable mechanical rotating way. 

4.Perfect dustproof, waterproof, and anti-corrosion ability. 

5.Full set of steel galvanized foundation frame and the vertical and horizontal  dwang for option.

    Sticking for the perception of "Creating goods of high quality and making good friends with people today from all around the world", we constantly set the interest of shoppers to begin with for High Quality Air Break Switch 35kv Disconnector Switch 36kv Disconnector Gw4 Isolator Switch Factory Price, Welcome to post your sample and color ring to let us produce according to your specification.Welcome your inquiry! Looking forward to building long-term cooperation with you! High Quality Air Break Switch and Gw4 Disconnector Switch, We warmly welcome you to come to visit us personally. We hope to establish a long-term friendship based on equality and mutual benefit. If you want to get in touch with us, please do not hesitate to call. We will be your best choice.

     

    Service Conditions:

    • Altitude:1500m
    • Ambient temperature:-45°C ~45°C
    • Wind pressure:≤700pa(wind speed 34m/s)
    • Earthquake intensity:≤8 degree
    • Humidity of air:monthly≤90°C,daily≤95°C
    • Environment degree: degree III
    • Cannot be use on the condition of the danger of fire and blast,heavy pollution,chemical etching,strong shake ect.

     

     

     

     

     

     

    Technical parameter

    Rated voltage kV

    40.5

    Rated current A

    1250, 2000,

     Rated peak withstand current kA 

    Disconnector

    100,

    Earthing switch

    100

     Rated short-time withstand current and duration kA/s 

    Disconnector

    50/3

    Earthing switch

    50/3

    Rated short-time power frequency withstand voltage (rms.) kV 

    To earth

    95

    Between breaks

    118

    Rated lightning impulse withstand voltage (peak) kV 

    To earth

    185

    Between breaks

    215

    Creepage distance

    mm

    1025~1250

    Mechanical life

    times

    2000

    Motor supply power

    V

    ACV380

    Control system voltage

    V

    AC/DC 220V

    Small capacitive current during opening and closing A

    1

    Small inductive current during opening and closing A

    0.5

    Radio interference level μV

    ≤2500

     Rated static mechanical load of the terminal N 

    Horizontal longitudinal direction

    1000

    Horizontal transverse direction

    750

    Vertical force

    750

    Weight

    KG

    360~460