Metal Clad Switchgear 12KV 24KV 36KV KYN28 10KV AC Drawout Type Switchgear
product detail
Product Description
Product Description
KYN28 drawout type indoor metal-enclosed switchgear assemblies
Rated voltage: 12KV, 24KV, 35KV
Rated current: 200A ,630A,1250A, 2000A, 3150A
Breaking capacity: 25KA, 31.5KA
KYN28 indoor metal-clad switchgear is a complete power distribution device for 3.6~24kV, 3-phase AC50/60Hz, single-bus and single-bus sectionalized system. It is mainly used for power transmission of middle/small generators in power plants; power receiving, transmission for substations in power distribution and power system of factories, mines and enterprises, and starting of large high-voltage motor, etc., so as to control, protect and monitor the system. The switchgear meets IEC298, GB3906-91.In addition to be used with domestic VS1 vacuum circuit breaker, it can also be used with VD4 from ABB, 3AH5 from Siemens domestic ZN65A, and VB2 from GE, etc., it is truly a power distribution device with good performance.
In order to meet the requirement for wall mounting and front-end maintenance, the switchgear is equipped with a special current transformer, so that the operator can maintain and inspect it in front of the cubicle.
Service Environment
Altitude: not higher than 1000m;
Ambient temperature: upper limit +40℃, lower limit -15℃, and average value is not higher than 35℃ in 24 hours.
Relative humidity: daily mean RH not more than 95%, monthly mean RH not more than 90%;
No obvious pollutions such as erosion or combustible gas;
No frequent violent vibrations, earthquake intensity not above 8-magnitude;
Technical parameter:
No. |
Item |
Unit |
Data |
||
1 |
Rated voltage |
kV |
3.6, 7.2, 12 |
||
2 |
Rated frequency of circuit breaker |
Hz |
50 |
||
3 |
Rated current of circuit breaker |
A |
630, 1250, 1600, 2000, 2500, 3150, 4000 |
||
4 |
Rated current of switchgear |
A |
630, 1250, 1600, 2000, 2500, 3150, 4000 |
||
5 |
Rated short -time withstandcurrent(4s) |
kA |
16, 20, 25, 31.5, 40, 50 |
||
6 |
Rated withstands current (peak) |
kA |
40, 50, 63, 80, 100, 25 |
||
7 |
Rated short -circuit breaking current |
kA |
16, 20, 25, 31.5, 40, 50 |
||
8 |
Rated short -circuit closingcurrent(peak) |
kA |
40, 50, 63, 80, 100, 25 |
||
9 |
Rated |
1 min power frequency |
between poles, pole to earth |
kV |
24, 32, 42 |
insulation |
withstands voltage |
between open contacts |
kV |
24, 32, 48 |
|
leve |
Lightening impulse |
between poles, pole to earth |
kV |
40, 60, 75 |
|
withstands voltage (peak) |
between open contacts |
kV |
46, 70, 85 |
||
10 |
Protection level |
|
Shell: IP4X; IP2X when the CPT |
||
and CB doors are open |