Transformer 12kv 24kv 36kv SCB13 Dry Type Power Supply Transformer 15、100、1000kva

Using cutting-edge technology imported from overseas, we created the SC10, SCB10 series, and SC11, SCB11 series padding thin-insulation dry-type distributing transformers. Because the winding of these transformers is sealed with epoxy, the resin insulating dry-type transformer is explosion-proof, flame-retardant, low maintenance, and compact, allowing it to reach deep into the load center.

    product detail

    The key to our success is "Good Product or service High quality, Reasonable Rate and Efficient Service" for China Cheap price China Manufacturers Supply Yb Series Box Transformer Substation/Modular Box Transformer Substation/ Outdoor Photovoltaic Grid Transformer, Our aim is to assistance buyers recognize their aims. We're making terrific endeavours to realize this win-win circumstance and sincerely welcome you to definitely be a part of us! China Cheap price China Substation and Power Transformer Manufacturers, With the effort to keep pace with world's trend, we will always endeavor to meet customers' demands. If you want develop any other new solutions, we can customize them for yourself. If you feel interest in any of our goods or want develop new solutions, make sure you feel free to contact us. We're looking forward to forming successful business relationship with customers all over the world.

    Product Characteristics

    With the advanced technology brought in from averseas,we developed SC10,SCB10 series and SC11,SCB11 series padding thin-insulation dry-type distributing transformer whose winding is sealed up with epoxy,therefore the resin insulating dry-type transformer is flame-retardant,explosion-proof,free from maintenance and pollution,and it is compacted and can go deep into load center.

    Besides,with scientific and reasonable design and coating craftwork,The product has a small partial discharge, low noise and strong heat dissipation capability. It can be equipped with an intelligent temperature controller with fault alarm, over temperature alarm and over temperature trip. And the black box function, and connected to the computer through the RS485 serial interface, can be centralized monitoring and control.

    Our company's dry-type transformers are widely used in transmission and transformation point systems, such as hotels, restaurants, airports, high-rise buildings, commercial centers, residential quarters and other important places, as well as subways, smelting power plants, ships, marine drilling platforms and other environmentally harsh places.

    Iron Core
    The iron core is made of imported high-quality cold-rolled silicon steel sheet, which is fully connected with oblique seam structure. The core column is banded with F-grade non-weft adhesive tape. The surface of the core is encapsulated with epoxy resin, which reduces the no-load loss, no-load current and core noise. Parts and fasteners are specially surface treated to further improve the appearance quality of the product.


    High Voltage Winding
    The high-voltage winding is vacuum-cast with filled epoxy resin, which greatly reduces the partial discharge and improves the electrical strength of the coil. The inner and outer walls of the winding are filled with glass fiber mesh plates, which enhances the mechanical strength of the coil and improves the product against sudden short circuit. The ability of the coil will never crack.


    Main Features
    1. Technical standards: IEC 60076-1-5, IEC 61378-1:1997, GB 1094.11-2007, GB 1094.1-2013
    2. Rated capacity: 30-4000kVA
    3. Voltage grade: 10kV, 20kV, 35kV, etc
    4. Voltage regulation method: Non-excited or loaded
    5. Frequency: 50Hz or 60Hz
    6. Phase: three phase 
     7. Coonnection: Y,yn0,  D,yn11, etc.
     8. Cooling type: AN(Automatic cooling) or AF(Wind cooling)
     9. Insulation grade: F
     10. Protection grade: IP00, IP20(indoor), IP23(outdoor)
    11. Conditions of Use:
    The altitude is less than 1000 meters and the ambient temperature is not higher than 40 degrees Celsius. Above the above range, technical adjustments should be made in accordance with the standards.

    Rated Capacity

    Voltage Ratio

    Vector Group

    No-load Losses(kw)

    Impedance

    30kva

    380v/3kv/6kv/11kv/33kv

    Dyn11/Yd11/Yyno

    0.1

    4%

    50kva

    380v/3kv/6kv/11kv/33kv

    Dyn11/Yd11/Yyno

    0.13

    4%

    100kva

    380v/3kv/6kv/11kv/33kv

    Dyn11/Yd11/Yyno

    0.2

    4%

    200kva

    380v/3kv/6kv/11kv/33kv

    Dyn11/Yd11/Yyno

    0.34

    4%

    315kva

    380v/3kv/6kv/11kv/33kv

    Dyn11/Yd11/Yyno

    0.42

    4%

    500kva

    380v/3kv/6kv/11kv/33kv

    Dyn11/Yd11/Yyno

    0.6

    4%

    1000kva

    380v/3kv/6kv/11kv/33kv

    Dyn11/Yd11/Yyno

    1.15

    4.5%

    1250kva

    6kv/11kv/33kv

    Dyn11/Yd11/Yyno

    1.15

    4.5%

    1600kva

    380v/3kv/6kv/11kv/33kv

    Dyn11/Yd11/Yyno

    2.3

    4.5%

    2500kva

    11kv/33kv

    Dyn11/Yd11/Yyno

    2.3

    4.5%

    4000kva

    11kv/33kv

    Dyn11/Yd11/Yyno

    2.8

    5%